Product

20908 USB Reusable Data Logger

FlashLink® USB Reusable Data Logger, Model 20908

The FlashLink USB Reusable Data Logger can monitor temperature sensitive commodities in storage facilities, processing environments and during transportation. The built-in USB connector allows for easy programming of logging parameters and downloading recorded data to a PC. Users can configure sample intervals, high and low alarm limits, automatic or manual start, skip alarm, alarm delay, record data in loop mode or to stop when memory is full. Downloaded temperature history is displayed as a PDF with a graph and summary data, including highest and lowest temperatures, average temperature, time spent in alarm, degree minutes and MKT calculations, and when the unit was started, stopped and downloaded. Tabular data and CSV files are also generated by the software, showing details for each data point.

This data logger is an important tool for monitoring ambient air in temperature controlled environments, such as cold storage warehouses, distribution centers, processing areas and in delivery vehicles. It provides valuable temperature history used for making cold chain management decisions, as well as for validation, thermal mapping, and documentation required for audits, inspections and regulatory compliance. FlashPDF Program Manager Software downloads reports as PDF and CSV files, which are easily shared by email and archived.

Reusable USB data logger with external probe

FlashLink® Reusable Data Logger with External Probe, Model 20902 & 20903

The FlashLink USB Reusable Data Logger is also available in two models with single channel, external sensors; one with a blunt tip and one with a sharp tip penetration probe. These reusable loggers have a measurement range of -40°F to 185°F (-40°C to 85°C) and feature a large easy-to-read display which shows the current temperature reading. It also permits viewing the statistics of stored data without downloading; including maximum, minimum, and average temperature, high alarm limit and time in alarm. The USB connections allow for programming and downloading using DeltaTrak's FlashPDF Program Manager or USB Program Manager desktop software. DeltaTrak’s NIST traceable USB Reusable Loggers are essential tools for documenting conditions of temperature sensitive commodities in order to assure quality and integrity.

 

20932 C 15B1

FlashLink Certified Vaccine Data Logger with Glycol Bottle (WHO prequalified), Model 20938

The FlashLink Certified Vaccine Data Logger with Glycol Bottle is designed for monitoring temperature conditions inside storage units where vaccines and other temperature sensitive pharmaceuticals are kept. This reusable logger features a large, easy-to-read LCD and an external probe sealed in a 5mL glycol bottle. The glycol prevents false alarms by buffering the probe against sudden and expected temperature fluctuations during normal use, such as frequent door openings and cycling of the refrigerator or freezer. The glycol also emulates temperature changes experienced by most common fluids in storage, to give more accurate readings. The logger attaches to the outside of the storage door, while the sensor bottle is placed inside, allowing users to read current and minimum/maximum temperatures without opening the unit. A red LED alarm and low battery indicator are also visible on the display. This logger is prequalified by the World Health Organization (WHO) as an E006 Temperature Monitoring Device, under their Performance Quality Safety code PQS E006/026, and is compatible with FDA, CDC and WHO guidelines. Certificates are available for ISO 17025 and NIST calibration.
 

Model 20908

FlashLink® USB Reusable Data Logger, Model 20908

20908 reusable USB data Logger
  • Single channel, internal sensor for ambient air temperature
  • User Programmable: manual or automatic start, sample interval, alarm limits, data tags
  • Large, easy to read LCD display
  • Remaining Battery Indicator (low battery)
  • Trip history statistics available on LCD
  • NIST traceable and CE Mark
  • USB Connection
FeatureSpecification
DeltaTrak manufactures products under an ISO 9000 registered quality management system
Measurement Range -40°F to 122°F (-40°C to 50°C)
Temperature Resolution 0.1°F/°C
Accuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);
±2.0°F above 77°F (±1.0°C above 25°C);
±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 3823 data points
Data Download Time 2 seconds typical for 3823 points
Programable Alarm Levels High & Low levels over entire range, displayed on LCD
Battery Coin Cell Lithium Battery, LCD % remaining power indicator
Dimensions/Body 1.575" x 3.189" x .575" (40mm x 81mm x 15mm)
Casing PC/ABS plastic
Weight 1.3 oz. (36 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, NIST traceable, RoHS Compliant
Display LCD, Red LED Alarm
Waterproof Rating IP64 with silicon cap on
Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
System Requirements Windows PC with current operating system, Adobe Reader
Programming FlashPDF Program Manager software
Download Requirements Direct USB connection
To download a pdf version of this specification sheet please click here 20908 reusable USB data Logger

Model 20902-20903

FlashLink® Reusable Data Logger with External Probe, Model 20902 & 20903

Reusable Data Logger with External Probe
  • Single channel, external probe for product core temperature
  • User Programmable: manual or automatic start, sample interval, alarm limits, data tags
  • Large, easy to read LCD display
  • Remaining Battery Indicator (low battery)
  • Trip history statistics available on LCD
  • NIST traceable and CE Mark
  • USB Connection
FeatureSpecification
Probe Measurement Range -40°F to 185°F (-40°C to 85°C)
Probe Size: Penetration tip (20902) 0.14in Dia x 3.98in L (3.5mm Dia x 101mm L), 3.28 ft (1m) Teflon cable
Blunt tip (20903) 0.15in Dia x 0.98in L (3.8mm Dia x 25mm L), 3.28 ft (1m) Teflon cable
Temperature Resolution 0.1°F/°C
Accuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C);
±2.0°F above 77°F (±1.0°C above 25°C)
±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 3823 data points
Data Download Time 2 seconds typical for 3823 points
Programable Alarm Levels High & Low levels over entire range
Battery (CR2032) 3.6V Lithium/18 months
Dimensions/Body 1.575" x 3.189" x 0.575" (40mm x 81mm x 13mm)
Casing PC/ABS plastic
Certification CE Mark, NIST traceable, RoHS Compliant
Display LCD, Red LED Alarm
Waterproof Rating IP64 with silicon cap on
Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH
System Requirements Windows PC with current operating system, Adobe Reader
Programming FlashPDF Program Manager software or USB Program Manager software
Download Requirements Direct USB connection
To download a pdf version of this specification sheet please click here Reusable Data Logger with External Probe

 

Model 20938

FlashLink® Reusable Data Logger with External Probe,

Model 20938

20932 C 15B1
  • Large, easy to read LCD Display
  • Certified, NIST traceable
  • Remaining Battery Indicator on LCD (low battery)
  • Detachable external temperature sensor, sealed in 5mL glycol bottle
  • Hi/Low programmable alarms for out of range conditions
  • User programmable logging intervals
  • USB Connection
  • Temp range -40˚F to 104˚F / -40˚C to 40˚C
  • 32,496 data points
FeatureSpecification
Measurement Range -40°F to 104°F (-40°C to 40°C)
Temperature Resolution 0.1°F/°C
Accuracy ±1.0°F from 14°F to 77°F (±0.5°C from -10°C to 25°C); ±2.0°F above 77°F (±1.0°C above 25°C) ±2.0°F below 14°F (±1.0°C below -10°C)
Data Capacity 32,496 data points
Data Download Time 2 seconds typical for 3823 points
Programmable Alarm Levels High & Low levels over entire range, displayed on LCD
Battery Coin Cell Lithium battery, LCD % remaining power indicator
Dimensions/Body 1.575" x 3.189" x .575" (40mm x 81mm x 15mm)
Logger Casing PC/ABS plastic
External Bottle 5mL PETG* Sterile Bottle - 21CFR compliance information available
Glycol Buffer Propylene glycol (GRAS** classified)
Weight 2.56 oz. (70 grams)
Certification CE Mark, NIST traceable, RoHS Compliant
Display LCD, Red LED Alarm
Waterproof Rating IP64 (with silicone cap)
Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
Shelf Life 2 years
Min. System Requirements Windows PC with XP or higher
Download Requirements Direct USB connection to PC, FlashPDF Program Manager Software v4.5 or higher
DeltaTrak manufactures products under an ISO 9001:2008 registered quality management systeme
* Polyethylene terephthalate copolymer ** Generally Recognized As Safe
            To download a pdf version of this specification sheet please click here Reusable Data Logger with External Probe