Product

FlashLink® CT -80°C Dry Ice Data Logger,

Model 20762-20764 & 20769

2076X-FlashLink CT -80 15I1

The The FlashLink® -80°C Dry Ice Data Logger, Model 20762, 20763, 20764 and 20769, is used in shipments requiring dry ice to keep temperature-sensitive commodities frozen. This is a rugged data logger available in 5, 15, 45 or 75 day recording times.

40535

FlashLink® USB PDF -80°C In-Transit Loggers,

Model 40535-40538

DeltaTrak’s FlashLink® USB PDF -80°C In-Transit Loggers are ideal cold chain management tools for monitoring temperature sensitive commodities that must be frozen and travel through the supply chain at very low temperatures, especially those shipped with dry ice. This single-use data logger is equipped with a USB connector and on-board software to enable immediate download of data when a load arrives. It provides temperature history as PDF and CSV reports, and can be purchased in 5, 15, 45, and 75 day logging periods. Its patented Shadow Log® feature guarantees that trip data is available even if the operator fails to start the unit.

 

Models 20762-20764 & 20769

FlashLink® CT -80°C Dry Ice Data Logger, Model 20762-20764 & 20769

The FlashLink® -80°C Dry Ice Data Logger, Model 20762, 20763, 20764 and 20769, is used in shipments requiring dry ice to keep temperature-sensitive commodities frozen. This is a rugged data logger available in 5, 15, 45 or 75 day recording times.

2076X FlashLink CT 80

Overview

Models 5-Day 15-Day 45-Day 75-Day
20762 20763 20764 20769

FlashLink® CT -80°C Data Loggers are ideal for monitoring the transport of Time and Temperature Sensitive (TATS) materials such as carbon fiber prepreg, which are typically shipped with dry ice in order to keep them frozen. The logger provides a complete record of temperature conditions during the shipping and handling of costly TATS materials, helping to ensure and verify the quality and safety of these products.

  • Compact, single-use, in-transit temperature data logger
  • Ideal for dry ice shipments
  • NIST traceable, CE Mark, BSS 7061 Compliant
  • Print data using CT Graphics Printer or download data to a PC using CT-USB adapter
  • Patented Shadow Log™ feature guarantees data even if the operator forgets to start the device
  • FlashPDF software option (21 CFR Part 11 Compliant)
CT Graphics Printer

The optional CT Graphics Printer, downloads data from the logger in five seconds and prints out the data almost immediately without the need for a PC. You can see temperature excursions while still on the loading dock for faster acceptance or rejection of a load. FlashLink CT printer for use with FlashLink®-80°C CT Data Loggers.

The CT Manager Software with CT-USB adapter, provides the user an easy way to retrieve recorded data from the data logger and download and store it on a PC. The software gives you the ability to analyze the data and output in in multiple formats.

Use the optional FlashPDF, software to create an Adobe® PDF file from the data retrieved from the logger. The file is automatically saved on a PC, ready to be printed or emailed.

Specifications

FlashLink® CT -80°C Data Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 9001:2008 registered quality management system
Measurement Range -80°C to 47°C (-112°F to 117°F)
Temperature Accuracy 0.5°C (±1.0°F) From -60°C to 30°C (-76°F to 86°F)
1°C (±2°F) From -80°C to -60°C (-112°F to -76°F)
2°C (±3°F) From 30°C to 47°C (86°F to 117°F)
Temperature Resolution 0.1°C/F
Data Capacity 3,824 Data points
Data Download Time 5 seconds
Factory Programmable Alarm Levels High & low limits over entire range
LED Indicators Flashing red for alarm, green for active
Battery Single AA Lithium Battery
Dimensions 4.03" x 1.75" x 1.18" (102.55 mm x 44.5 mm x 30 mm)
Weight 2.82 oz. (80 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
IP Rating 68 (with cap on)
Certification CE Mark, NIST traceable calibration, RoHS Compliant, BSS 7061 Compliant
System Requirements Windows PC with current operating system, Adobe Reader, FlashPDF software
Download Requirements 8-Pin to USB Adapter
Download FlashLink® CT -80°C Dry Ice Data Logger Spec Sheet Flashlink CT -80 Data Logger

Packaging

>FlashLink CT -80C Dry Ice Data Logger, Model 20762-20764 & 20769

Accessories

Accessory: Model 20719 - FlashLink 8 pin USB Adapter Kit

Model 20719 - FlashLink 8 pin USB Adapter Kit

Model 20719: FlashLink 8 Pin to USB High Speed Adapter Kit

  • Eight pin to USB adapter
  • USB extension cable included

Download FlashLink 8 Pin to USB High Speed Adapter Kit Spec Sheet

Software

FlashPDF

FlashPDF

FlashPDF is a simple program used to create a locked PDF file with data downloaded from any FlashLink data logger. Once installed on a Windows PC, the program runs automatically when a logger is connected via the USB adapter. The PDF is then created, saved, and displayed on screen automatically. These PDF files can easily be archived and emailed.

More information on FlashPDF Software

Models 40535-40538

 

FlashLink® USB PDF -80°C In-Transit Loggers,

Model 40535-40538

40535
FlashLink®USB PDF -80°C In-Transit Loggers are ideal cold chain management tools for monitoring temperature sensitive commodities that must be frozen and travel through the supply chain at very low temperatures, especially those shipped with dry ice. This single-use data logger is equipped with a USB connector and on-board software to enable immediate download of data when a load arrives. It provides temperature history as PDF and CSV reports, and can be purchased in 5, 15, 45, and 75 day logging periods. Its patented Shadow Log® feature guarantees that trip data is available even if the operator fails to start the unit.

Overview

Models5-Day15-Day45-Day75-Day
°C Models 40535 40536 40537 40538

FlashLink® USB PDF -80°C In-Transit Loggers are ideal for monitoring the transport of Time and Temperature Sensitive (TATS) materials such as carbon fiber prepreg, which are typically shipped with dry ice in order to keep them frozen. They can also be used to track shipments of biological materials for the Life Science industry. The loggers provide a complete record of temperature conditions during shipping and handling, helping to ensure and verify the quality and safety of these costly materials.

  • Large, easy to read LCD display
  • Trip history statistics available on LCD
  • Remaining battery life indication (low battery)
  • Single-use
  • USB Connection
  • NIST traceable, CE Mark, BSS 7061 Compliant
  • IP54 water-resistant rating
  • Download temperature data as PDF report with free FlashPDF software
  • Patented Shadow Log feature guarantees temperature data
    even if the operator fails to start the data logger

Specifications

FeatureSpecification
DeltaTrak manufactures products under an ISO 9001:2008 registered quality management system
Measurement Range -80°C to 47°C
Temperature Resolution 0.1°C/F over full temperature measurement range
Accuracy ±0.5°C from 0°C to 25°C
±1.0°C from 25°C to 47°C
±1.0°C from -40°C to 0°C
±1.7°C from -80°C to -40°C
Data Capacity 3,823 points
Data Download Time 5 seconds typical for 3823 points
Factory Programmable Alarm Levels High & Low levels over entire range, displayed on LCD
Battery Single AA Lithium battery
Dimensions 1.57" x 3.67" x 0.94" (40mm x 93.5 mm x 24mm)
Casing PC/ABS plastic
Weight 1.9 oz. (54 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, NIST traceable, ROHS Compliant, BSS 7061 Compliant
FAA Compliance RTCA/DO-160
Display °C Scale on LCD, Red LED Alarm
IP Rating IP54 (with silicon cap on)
Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
System Requirements Windows PC with current operating system, Adobe reader
Download Requirements Direct USB connection

 To download a pdf version of this specification sheet please click here FlashLink Dry Ice data logger

Packaging

The pillow style sleeve is designed to provide a cushion of air around the FlashLink USB PDF -80°C Logger. This allows the unit to more closely reflect the temperatures that products experience during transport, by preventing direct contact between the logger and the dry ice.

The back of the sleeve contains shipper instructions in English and Spanish, and receiver instructions in English, Spanish, Chinese and Japanese. An image of the LCD identifies the icons that appear on the screen. Each end of the sleeve closes with two foldable flaps, securing the logger inside and making it easy to remove and download when a shipment arrives.

Front
Back